產(chǎn)品詳情
Solenoid Driver
1-channel isolated barrier,24 V DC supply(loop powered),Current limit 45 mA at 12 V DC,Housing width 12.5 mm,Up to SIL3 acc.to IEC 61508,Explosion protection:Ex-Output,Output rated operating current:45 mA,SIL/IEC 61508
KCD2-SR-2.SP

Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-SR-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Usable as signal splitter(1 b and 2 outputs),Relay contact output,Fault relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-ST-1.LB
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 active transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-1.LB.SP
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 active transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-2
Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 active transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-2.SP
Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 active transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 active transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-Ex2
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 active transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-ST-Ex2.SP
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 active transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-STC-Ex1.ES.SP
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL3 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.HC.SP
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Low power dissipation,Suitable for long field cables(>1000 m),Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-SCD-Ex1
SMART Current Driver
1-channel isolated barrier,24 V DC supply(Power Rail),Current output up to 650Ωload,HART I/P and valve ber,Lead breakage monitoring,Accuracy 0.1%,Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508
KCD2-SR-1.LB
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Usable as signal splitter(1 b and 2 outputs),Relay contact output,Fault relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-SR-Ex1.LB
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Usable as signal splitter(1 b and 2 outputs),Relay contact output,Fault relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-SR-Ex2
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-STC-Ex1
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-UT2-Ex1
Universal Temperature Converter
1-channel isolated barrier,24 V DC supply(Power Rail),Thermocouple,RTD,potentiometer or voltage b,Current output 0/4 mA...20 mA,Sink or source mode,Configurable by PACTware,Line fault(LFD)and sensor burnout detection,Input:Temperature,Rated voltage:19...30 V DC,Output:4-20 mA
KCD2-E2L
Sensor output interface terminal
1-channel terminal amplifier,NAMUR sensor b,DC 24 V supply voltage,Standard interface for prevention of signal transmission errors,Switching status indicator,yellow LED
KCD2-EL
Sensor output interface terminal
1-channel terminal amplifier,NAMUR sensor b,DC 24 V supply voltage,Standard interface for prevention of signal transmission errors,Switching status indicator,yellow LED
KCD2-R
Sensor output interface terminal
Relay output with 1 pole,yellow LED indicates switching state,Free-wheeling diode,Compact terminal housing,Clips onto standard 35 mm rail to DIN EN 50 022,Degree of protection IP20
KCD2-RR-Ex1
Temperature Repeater
1-channel isolated barrier,24 V DC supply(Power Rail),Resistance and RTD b(Pt100,Pt500,Pt1000),Resistance output,Accuracy 0.1%,Line fault detection(LFD)for Pt100,Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Rated voltage:19...30 V DC,Explosion protection:Ex-Input,Field circuit:Resistance,Safe area:Resistance,Transfer direction:to the control system
KCD2-SOT-Ex1.LB
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-RR-Ex1-Y1
Temperature Repeater
1-channel isolated barrier,24 V DC supply(Power Rail),Resistance and RTD b(Pt100,Pt500,Pt1000),Resistance output,Accuracy 0.1%,Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Rated voltage:19...30 V DC,Explosion protection:Ex-Input,Field circuit:Resistance,Safe area:Resistance,Transfer direction:to the control system
KCD2-SCD-1
SMART Current Driver
1-channel signal conditioner,24 V DC supply(Power Rail),Current output up to 650Ωload,HART I/P and valve ber,Lead breakage monitoring,Accuracy 0.1%,Housing width 12.5 mm,Up to SIL2 acc.to IEC 61508
KCD2-STC-1
SMART Transmitter Power Supply
1-channel signal conditioner,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Housing width 12.5 mm,Up to SIL2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.2O
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Signal splitter(1 b and 2 outputs),Dual output 0/4 mA...20 mA or 0/1 V...5 V,Terminal blocks with test sockets,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:18...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.ES
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL3 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD0-LGH
Place Holder Barrier
IS K-System place holder module,Housing width 12.5 mm,Marshalling for field and control side circuits,Jumper configurable
KCD2-E3
Sensor output interface terminal
1-channel terminal amplifier,NAMUR sensor b,DC 24 V supply voltage,Standard interface for prevention of signal transmission errors,Switching status indicator,yellow LED
KCD2-SCD-1.SP
SMART Current Driver
1-channel signal conditioner,24 V DC supply(Power Rail),Current output up to 650Ωload,HART I/P and valve ber,Lead breakage monitoring,Accuracy 0.1%,Housing width 12.5 mm,Connection via spring terminals,Up to SIL2 acc.to IEC 61508
KCD2-SCD-Ex1.HC
SMART Current Driver
1-channel isolated barrier,24 V DC supply(Power Rail),Current output up to 625Ωload,HART I/P and valve ber,Lead breakage monitoring,Suitable for long field cables(>1000 m),Terminal blocks with test sockets,Up to SIL 2 acc.to IEC 61508
KCD2-SCD-Ex1.SP
SMART Current Driver
1-channel isolated barrier,24 V DC supply(Power Rail),Current output up to 650Ωload,HART I/P and valve ber,Lead breakage monitoring,Accuracy 0.1%,Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508
KCD2-SOT-Ex2
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SR-1.LB.SP
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Usable as signal splitter(1 b and 2 outputs),Relay contact output,Fault relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-SR-2
Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-SR-Ex2.SP
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,Relay contact output,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:relay,SIL/IEC 61508
KCD2-ST-Ex1.LB
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 active transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-STC-1.2O
SMART Transmitter Power Supply
1-channel signal conditioner,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Signal splitter(1 b and 2 outputs),Dual output 0/4 mA...20 mA or 0/1 V...5 V,Terminal blocks with test sockets,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:18...30 V DC,SIL/IEC 61508
KCD2-STC-1.SP
SMART Transmitter Power Supply
1-channel signal conditioner,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Housing width 12.5 mm,Connection via spring terminals,Up to SIL2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.2O.DE
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Signal splitter(1 b and 2 outputs),Dual output 0/4 mA...20 mA or 0/1 V...5 V,Terminal blocks with test sockets,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:18...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.HC
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Low power dissipation,Suitable for long field cables(>1000 m),Terminal blocks with test sockets,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-STC-Ex1.SP
SMART Transmitter Power Supply
1-channel isolated barrier,24 V DC supply(Power Rail),Input for 2-wire SMART transmitters and current sources,Output for 4 mA...20 mA or 1 V...5 V,Sink or source mode,Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:2-wire transmitter,Rated voltage:19...30 V DC,SIL/IEC 61508
KCD2-UT2-1
Universal Temperature Converter
1-channel signal conditioner,24 V DC supply(Power Rail),Thermocouple,RTD,potentiometer or voltage b,Current output 0/4 mA...20 mA,Sink or source mode,Configurable by PACTware,Line fault(LFD)and sensor burnout detection,Input:Temperature,Rated voltage:19...30 V DC,Output:4-20 mA
KCD0-LGH.SP
Place Holder Barrier
IS K-System place holder module,Marshalling for field and control side circuits,Jumper configurable,Housing width 12.5 mm,Connection via spring terminals
KCD0-SD-Ex1.1245.SP
Solenoid Driver
1-channel isolated barrier,24 V DC supply(loop powered),Current limit 45 mA at 12 V DC,Housing width 12.5 mm,Connection via spring terminals,Up to SIL3 acc.to IEC 61508,Explosion protection:Ex-Output,Output rated operating current:45 mA,SIL/IEC 61508
KCD2-E1
Sensor output interface terminal
1-channel terminal amplifier,NAMUR sensor b,DC 24 V supply voltage,Standard interface for prevention of signal transmission errors,Switching status indicator,yellow LED
KCD2-RR-Ex1.SP
Temperature Repeater
1-channel isolated barrier,24 V DC supply(Power Rail),Resistance and RTD b(Pt100,Pt500,Pt1000),Resistance output,Accuracy 0.1%,Line fault detection(LFD)for Pt100,Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Rated voltage:19...30 V DC,Explosion protection:Ex-Input,Field circuit:Resistance,Safe area:Resistance,Transfer direction:to the control system
KCD2-SCD-Ex1.HC.SP
SMART Current Driver
1-channel isolated barrier,24 V DC supply(Power Rail),Current output up to 625Ωload,HART I/P and valve ber,Lead breakage monitoring,Suitable for long field cables(>1000 m),Connection via spring terminals,Up to SIL 2 acc.to IEC 61508
KCD2-SON-Ex1
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs(resistive acc.to EN 60947-5-6),Line fault transparency(LFT),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SON-Ex1.R1
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs(resistive),Application-specific outputs,Line fault transparency(LFT),Usable as signal splitter(1 b and 2 outputs),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SON-Ex1.SP
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs(resistive acc.to EN 60947-5-6),Line fault transparency(LFT),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SON-Ex2
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs(resistive acc.to EN 60947-5-6),Line fault transparency(LFT),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SON-Ex2.R1
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs(resistive),Application-specific outputs,Line fault transparency(LFT),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SON-Ex2.SP
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs(resistive acc.to EN 60947-5-6),Line fault transparency(LFT),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-1.LB
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-1.LB.SP
Switch Amplifier
1-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-2
Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-2.SP
Switch Amplifier
2-channel signal conditioner,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-Ex1.LB.SP
Switch Amplifier
1-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR b,2 passive transistor outputs,Usable as signal splitter(1 b and 2 outputs),Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508
KCD2-SOT-Ex2.SP
Switch Amplifier
2-channel isolated barrier,24 V DC supply(Power Rail),Dry contact or NAMUR bs,2 passive transistor outputs,Reversible mode of operation,Line fault detection(LFD),Housing width 12.5 mm,Connection via spring terminals,Up to SIL 2 acc.to IEC 61508,Input:NAMUR sensor,Rated voltage:19...30 V DC,Output:Transistor,SIL/IEC 61508